Products
- Connectors[2]
- Terminal Blocks[1]
- Terminals[6]
- Contactors[6]
- Electrical Plugs & Sockets[6]
- Fuses[6]
- Other Electrical Equipment[4]
- Inverters & Converters[2]
- Switching Power Supply[1]
- Uninterrupted Power Supply (UPS)[5]
- Voltage Regulators/Stabilizers[6]
- Relays[6]
- Flow Switches[1]
- Other Switches[2]
- Cable Manufacturing Equipment[1]
- Electrical Wires[3]
- Electrical Ceramics[1]
- Meat Product[1]
- Goose[3]
- Turkey[3]
- Bean Snacks[2]
- Fans[1]
- Starters[1]
- Emergency Lights[2]
- Other Lights & Lighting Products[6]
- Welding Fluxes[1]
- Welding Wires[1]
- Arc Welders[6]
- Other Welding Equipment[3]
- Clamp Meters[1]
- Energy Meters[6]
- Multimeters[1]
- Power Meters[1]
- Voltage Meters[1]
- Temperature Instruments[1]
- Alarm[6]
- Other Police & Military Supplies[1]
- Traffic Light[1]
- Pliers[2]
Contact Us
- Contact Person : Ms. chen Candy
- Company Name : Andeli Group Co., Ltd.
- Tel : 86-577-62731666
- Fax : 86-577-62731777
- Address : Zhejiang,Yueqing,NO.208,WEIQI ROAD,YUEQING ECONOMIC DEVELOPMENT ZONE,YUEQING,ZHEJIANG,CHINA
- Country/Region : China
- Zip : 325600
Product Detailed
Related Categories:Relays
Related Product Searches:JRS2 Series Thermal Relay,High Quality Thermal Relay,Thermal Relay JRS2-400/F
1. standard: IEC60947-4-1
2. CE certification
3. connect with CJX1
4. OEM business is acceptable
1.ApplicationJRS2 thermal relay is suitable for AC 50/60Hz, voltage up to 660V and current up to 630A,general AC motor of long or discontinuous long operation, used as overload protection and hasthe functions of breaking phase protection, temperature compensation, and trip indication. Itcan automatically and manually get back. It can be fixed with contactor CJX1 together, also beindependtly fixed. The product conforms to IEC60947-4-1 stardand.2. Motion Characteristic: Three-phase Balance Motion Time Related Product Searches:JRS2 Series Thermal Relay,High Quality Thermal Relay,Thermal Relay JRS2-400/F
No | Times of the setting current | Motion time | Start condition | Ambient temperature | ||
1 | 1.05 | >2h | Cold state | 20±5oC | ||
2 | 1.2 | <2h | Heat state(Following the No.1 test) | |||
3 | 1.5 | <4min | ||||
4 | 7.2 | 10A | 2s< Tp≤10s | ≤63A | Cold state | |
10 | 4s< Tp≤10s | >63A |
No | Times of the setting current | Motion time | Start condition | Ambienttemperature | |
Any two phases | Another phase | ||||
1 | 1.0 | 0.9 | >2h | Cold state | 20±5oC |
2 | 1.15 | 0 | <2h | Heat state(Following the No.1 test) |
Type | Number | Setting range(A) | For contactor | Type | Number | Setting range(A) | For contactor | |
JRS2-12.5/Z | 0A | 0.1~0.16 | CJX1-09CJX1-12 | JRS2-25/Z | 0A | 0.1~0.16 | CJX1-16CJX1-22 | |
0C | 0.16~0.25 | 0C | 0.16~0.25 | |||||
0E | 0.25~0.4 | 0E | 0.25~0.4 | |||||
0G | 0.4~0.63 | 0G | 0.4~0.63 | |||||
0J | 0.63~1 | 0J | 0.63~1 | |||||
0K | 0.8~1.25 | 0K | 0.8~1.25 | |||||
1A | 1~1.6 | 1A | 1~1.6 | |||||
1B | 1.25~2 | 1B | 1.25~2 | |||||
1C | 1.6~2.5 | 1C | 1.6~2.5 | |||||
1D | 2~3.2 | 1D | 2~3.2 | |||||
1E | 2.5~4 | 1E | 2.5~4 | |||||
1F | 3.2~5 | 1F | 3.2~5 | |||||
1G | 4~6.3 | 1G | 4~6.3 | |||||
1H | 5~8 | 1H | 5~8 | |||||
1J | 6.3~10 | 1J | 6.3~10 | |||||
1K | 8~12.5 | 1K | 8~12.5 | |||||
2S | 10~14.5 | 2A | 10~16 | |||||
2B | 12.5~20 | |||||||
2C | 16~25 | |||||||
Type | Number | Setting range(A) | For contactor | Type | Number | Setting range(A) | For contactor | |
JRS2-32/Z | 1G | 4~6.3 | CJX1-32 | JRS2-63/F | 0K | 0.8~1.25 | CJX1-09~63 | |
1J | 6.3~10 | 1A | 1~1.6 | |||||
2A | 10~16 | 1B | 1.25~2 | |||||
2B | 12.5~20 | 1C | 1.6~2.5 | |||||
2C | 16~25 | 1D | 2~3.2 | |||||
2D | 20~32 | 1E | 2.5~4 | |||||
2Q | 25~36 | 1F | 3.2~5 | |||||
JRS2-45/Z | 0A | 0.1~0.16 | CJX1-32CJX1-38 | 1G | 4~6.3 | |||
0C | 0.16~0.25 | 1H | 5~8 | |||||
0E | 0.25~0.4 | 1J | 6.3~10 | |||||
0G | 0.4~0.63 | 1K | 8~12.5 | |||||
0J | 0.63~1 | 2A | 10~16 | |||||
0K | 0.8~1.25 | 2B | 12.5~20 | |||||
1A | 1~1.6 | 2C | 16~25 | |||||
1B | 1.25~2 | 2D | 20~32 | |||||
1C | 1.6~2.5 | 2E | 25~40 | |||||
1D | 2~3.2 | 2M | 32~45 | |||||
1E | 2.5~4 | 2T | 40~57 | |||||
1F | 3.2~5 | 2P | 50~63 | |||||
1G | 4~6.3 | JRS2-135 | 2H | 55~80 | CJX1-85CJX1-110 | |||
1H | 5~8 | 2W | 63~90 | |||||
1J | 6.3~10 | 2X | 80~110 | |||||
1K | 8~12.5 | 3H | 90~120 | |||||
2A | 10~16 | 3J | 110~135 | |||||
2B | 12.5~20 | JRS2-150 | 2H | 55~80 | CJX1-140 | |||
2C | 16~25 | 2W | 63~90 | |||||
2D | 20~32 | 2X | 80~110 | |||||
2Q | 25~36 | 3H | 90~120 | |||||
2R | 32~40 | 3J | 110~135 | |||||
8M | 36~45 | 3K | 120~150 | |||||
JRS2-80/Z | 1G | 4~6.3 | CJX1-45CJX1-63CJX1-75CJX1-85 | JRS2-180/F | 2H | 55~80 | CJX1-170CJX1-205 | |
8A | 11~17 | 2W | 63~90 | |||||
2B | 12.5~20 | 2X | 80~110 | |||||
2C | 16~25 | 3H | 90~120 | |||||
2D | 20~32 | 3J | 110~135 | |||||
2E | 25~40 | 3K | 120~150 | |||||
2F | 32~50 | 3L | 135~160 | |||||
2T | 40~57 | 3M | 150~180 | |||||
2P | 50~63 | JRS2-400 | 2K | 80~125 | CJX1-110~400 | |||
2V | 57~70 | 3B | 125~200 | |||||
2U | 63~80 | 3C | 160~250 | |||||
8W | 70~88 | 3D | 200~320 | |||||
JRS2-63/F | 0A | 0.1~0.16 | CJX1-09~63 | 3E | 250~400 | |||
0C | 0.16~0.25 | JRS2-630 | 3F | CJX1-400 | ||||
0E | 0.25~0.4 | 3G | ||||||
0G | 0.4~0.63 | |||||||
0J | 0.63~1 |